Home Product Catalog Order Catalog Wiring Diagram Contact Information
   
Model 420xxl - Specifications

view larger
  • Accommodates up to 5000 V Cable Voltage
  • Extended Temperature Range
  • Light Weight
  • Small Size
  • Encapsulated Shock Resistance
  • Metal Encased
  • Isolated Two-Wire Transmitters
  • Fast, Reliable Response
  • Low Cost Industrial Monitor
  • Current Overload Protection
  • Never Requires Calibration
  • Complete Electrical Isolation
  • Single Supply Voltage
  • Supply Reversal Protection

STANDARD CURRENT RANGES:
A.C. Amps, RMS
0-800, 0-1000



MAX WEIGHT: 24 OZ.

view larger
PERFORMANCE SPECIFICATION
With Optimum Load Resistance
Accuracy 1/4 of 1% of reading
Repeatability 0.25% Full Scale
Response Time 150 Milliseconds Maximum
Temperature Range -25 deg. C to 85 deg. C
Temperature Coefficient 0.04% F.S./ deg. C
Conductor Cable Voltage 5000 Volts (Insulated Cable)
Supply Voltage 5 to 40 V.D.C.
Signal Out 4 to 20 mA
Frequency Nominal 50 / 60 Hz
CONNECTION SPECIFICATION
Conductor Cable Size Up To 2.00" diameter
Isolation Input/Output/Case
Insulation Resistance
(Between Output and Case)
100 Meg. Ohm Min.
@500 V.D.C.

CHARACTERISTIC CURVE
OPTIMUM LOAD RESISTANCE
The optimum load resistance is actually the sum of the line resistance, receiver resistances and added external load resistance. However, in many applications, the line resistance and receiver resistances are negligible in comparison to the added external load resistance. The following equation may apply:
RL = ( VS - 5 ) X 40 Where:  RL = Load Resistance in Ohms.
VS = Supply Voltage in Volts D.C.
Manufacturer maintains right to change specifications without notice; prices as of January 1, 2001.